• Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
  • Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
  • Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
  • Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
  • Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
  • Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area

Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area

Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Work Environment: Low-temperature Heat Pump
Samples:
US$ 1399/Set 1 Set(Min.Order)
| Order Sample
contact us before sample order
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area pictures & photos
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
US $999-1,199 / Set
Min. Order: 1 Set
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Secured Trading Service
Jiangsu, China
to see all verified strength labels (28)
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • After Sales Service
  • Contact Information
Overview

Basic Info.

Model NO.
SMHP-018TC3
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CB
Product Name
R290 Air to Water Heat Pump Water Heater
Refrigerant
R290
Function
Heating Cooling Dhw
Type
Air Source Heat Pump
Working Temperature
-35 to 45 Degree Centigrade
Heat Exchanger
Danfoss
Heating Capacity
6kw to 18kw
Transport Package
Carton or Carton with Pallet
Specification
1187× 418× 805
Trademark
Sunrain or OEM
Origin
China
HS Code
8418612090
Production Capacity
1000000 Sets/Year

Packaging & Delivery

Package Size
118.00cm * 48.00cm * 145.00cm
Package Gross Weight
195.000kg

Product Description

Product Description

Sunrain R290 monoblock air to water heat pump water heater is specially designed for cold area, to satisfy family demand for heating, cooling and hot water. With EVI technology, Sunrain heatpump can have a stable perfomance even under -35ºC.  
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area

Key Features
 
* R290 refrigerant,low GWP(GWP=3)
* Energy class: A+++
* Heating+Cooling+DHW
* Full DC inverter compressor and fan motor
* -30ºC inverter
* WIFI smart control
* Outlet water temperature up to 75ºC
* BAFA CE certified
* SG ready function

  

                
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area

 

Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
 
                         TFT Touch Screen                                    Top Brand Inverter Compressor                         Blue Hydrophilic Fin Evaporators
                            Better View                                                      More Stable & Durable                                                 More Efficiency
 
 
Product Parameters
Model   SMHP-008TC3 SMHP-012TC3 SMHP-018TC3
Rated voltage / Frequency   380-415V/3N~/50(60)Hz
Heating¹ Capacity kW 4.1-12.1 4.30-15.20 7.24-21.90
Input Power kW 0.79-2.85 0.87-3.73 1.50-5.88
Input Current A 1.62-4.57 1.78-6.04 2.82-9.16
COP W/W 4.24-5.57 4.07-5.57 3.82-5.59
Heating² Capacity kW 4.05-12.15 4.25-14.55 6.36-19.45
Input Power kW 1.38-4.06 1.45-4.28 2.15-6.85
Input Current A 2.7-6.43 2.84-6.78 3.71-10.60
COP W/W 2.99-3.45 2.83-3.45 2.84-3.57
Cooling Capacity kW 3.65-8.59 3.65-11.04 4.55-17.20
Input Power kW 1.12-3.31 1.12-3.97 1.85-7.31
Input Current A 1.97-5.25 1.97-6.30 2.99-11.26
SCOP (Water Temp. At 35ºC)   4.84 4.74 4.79
SCOP (Water Temp. At 55ºC)   3.60 3.70 3.71
Rated Input Power kW 5.85 5.85 10.5
Rated Input Current A 10.0 10.0 17.0
Refrigerant Type/Charge/GWP .../kg R290/1.05/3 R290/1.05/3 R290/1.4/3
CO2  Equivalent / 0.0032t 0.0032t 0.0042t
Operation Pressure(Low Side) MPa 0.8 0.8 0.8
Operation Pressure(High Side) MPa 3.0 3.0 3.0
Maximum Allowable Pressure MPa 3.2 3.2 3.2
Electrical Shockproof / I I I
IP Class / IPX4 IPX4 IPX4
Max. Outlet Water Temp. ºC 75 75 75
Operating Ambient Temperature ºC -25~45 -25~45 -25~45
Water Piping Connections inch G1 G1 G1-1/4
Rated Water Flow m³/h 1.40 2.06 3.1
Water Pressure Drop kPa 20 20 55
Min/Max Water Pressure MPa 0.1/0.3 0.1/0.3 0.1/0.3
Sound pressure Level dB(A) 43 54 56
Net Dimensions ( L×W×H ) mm 1287×448×904 1287×448×904 1187×488×1456
Net Weight kg 134 134 195
Packaging & Shipping
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area

                                         Carton Box                                                                        Carton Box With Pallet

Company Profile

Jiangsu Sunrain is a listed company engaged in renewable energy products for more than 26 years. We have 6 productions bases with annual turnover of more than 6 billion. Sunrain can supply a full range of air source heat pumps and heat pump components, like air to water heat pump water heaters, all in one heat pumps, split heat pump water heaters system, swimming pool heat pumps, commercial heat pump and monoblock heat pump for domest heating. It is more safe and flexible to do business with Sunrain.
                                  Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
                      

Big&Modernized Workshop                                                  Self Produced Components

Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area

   
                                 High Degree Of Automation                                                             Rich Exhibition Experience

Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area

 

After Sales Service

a. 2 years warranty for the whole heat pump

b. Free spare parts provided

c. OEM ODM project solution service available
Contact Information

Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area pictures & photos
Sunrain Bafa CE 18kw Evi Inverter R290 Air to Water Heat Pump for Cold Area
US $999-1,199 / Set
Min. Order: 1 Set
Diamond Member Since 2010

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
3765
Year of Establishment
1997-04-01